Create tag
POST/metalakes/:metalake/tags
Creates a tag in the metalake and returns it.
Sign in with a bearer token or a local user's password; see Authentication.
Request
Path Parameters
The name of the metalake
- application/json
Body
The name of the tag
A comment for the tag
properties
object
nullable
A map of properties for the tag
Responses
- 200
- 409
- 5xx
The new tag, with its comment, properties and audit information.
- application/vnd.gravitino.v1+json
- Schema
- Example (from schema)
- TagResponse
Schema
Possible values: [0]
Status code of the response
tag
object
A tag
The name of the tag
A comment about the tag
audit
object
required
Audit information for a Gravitino resource.
The user who created the resource
The time the resource was created
The user who last modified the resource
The time the resource was last modified
properties
object
Configured string to string map of properties for the tag
Whether the tag is inherited from the parent metadata object
{
"code": 0,
"tag": {
"name": "string",
"comment": "string",
"audit": {
"creator": "string",
"createTime": "2024-07-29T15:51:28.071Z",
"lastModifier": "string",
"lastModifiedTime": "2024-07-29T15:51:28.071Z"
},
"properties": {},
"inherited": true
}
}
{
"code": 0,
"tag": {
"name": "my_tag1",
"comment": "This is my tag1",
"properties": {
"key1": "value1",
"key2": "value2"
},
"audit": {
"creator": "gravitino",
"createTime": "2023-12-08T03:41:25.595Z"
},
"inherited": false
}
}
A tag with the same name already exists in the metalake.
- application/vnd.gravitino.v1+json
- Schema
- Example (from schema)
- TagAlreadyExistsException
Schema
Possible values: >= 1000 and <= 1100
HTTP response code
Internal type definition of the error
A human-readable message
Deprecated diagnostic stack trace. Enterprise omits it by default because it can expose internal implementation details. Operators can opt in for controlled diagnostics with gravitino.server.webserver.includeErrorStackTrace=true. See OWASP REST Security: Error handling and CWE-209.
{
"code": 1002,
"type": "string",
"message": "string"
}
{
"code": 1004,
"type": "TagAlreadyExistsException",
"message": "Failed to operate tag(s) [my_tag] operation [CREATE], reason [TagAlreadyExistsException]",
"stack": [
"org.apache.gravitino.exceptions.TagAlreadyExistsException: Gag my_tag already exists",
"..."
]
}
The server hit an internal error that the client usually cannot fix by changing the request.
- application/vnd.gravitino.v1+json
- Schema
- Example (from schema)
- Example
Schema
Possible values: >= 1000 and <= 1100
HTTP response code
Internal type definition of the error
A human-readable message
Deprecated diagnostic stack trace. Enterprise omits it by default because it can expose internal implementation details. Operators can opt in for controlled diagnostics with gravitino.server.webserver.includeErrorStackTrace=true. See OWASP REST Security: Error handling and CWE-209.
{
"code": 1002,
"type": "string",
"message": "string"
}
{
"code": 1002,
"type": "RuntimeException",
"message": "Internal Server Error",
"stack": [
"java.lang.RuntimeException: Internal Server Error"
]
}